Skip to product information
1 of 2

ALLTEST Tuberculosis Test Kits

ALLTEST Tuberculosis Test Kits

Manufactured to order (Lead time  3-4 Weeks)

The AllTest Tuberculosis Rapid Test Cassette (Whole Blood/Serum/Plasma) (REF: ITB-402) is a rapid chromatographic immunoassay designed for the qualitative detection of antibodies to tuberculosis (TB), including IgG, IgM and IgA, in human whole blood, serum or plasma specimens. This TB antibody test uses recombinant antigens to detect anti-TB antibodies and provides results in approximately 10 minutes. It is intended for professional in vitro diagnostic use and offers a convenient method of supporting the assessment of possible tuberculosis infection.

Tuberculosis is an infectious disease caused by bacteria that primarily affects the lungs and spreads through the air when an infected person coughs, sneezes or talks. Symptoms of active pulmonary TB may include a persistent cough, chest pain, fever, night sweats, fatigue and unexplained weight loss. Detecting antibodies to TB can provide additional information to support clinical assessment; however, antibody detection alone cannot confirm active tuberculosis. This rapid TB test should therefore be used alongside clinical findings and other appropriate diagnostic investigations, rather than as a standalone diagnostic method.

The Tuberculosis Rapid Test Cassette uses a qualitative, two-site sandwich immunoassay to detect antibodies against TB. The test membrane is coated with recombinant TB antigens. When a specimen containing anti-TB antibodies is added, the antibodies react with TB antigen-coated particles and migrate along the membrane. This reaction produces a coloured line in the Test (T) region.

A coloured line in the Control (C) region confirms that sufficient specimen has been added and that the test has functioned correctly.

This test detects antibodies to tuberculosis and does not directly detect the TB bacteria. It is a qualitative test and cannot determine the concentration of anti-TB antibodies or measure changes in antibody levels. A positive result indicates the presence of anti-TB antibodies but should not be used as the sole criterion for diagnosing active tuberculosis.

Results must be interpreted alongside clinical information and other appropriate diagnostic investigations. The test does not independently establish whether an infection is active or distinguish active disease from other possible explanations for antibody presence.

Results should be read at 10 minutes and must not be interpreted after 30 minutes. Store the test kit at 2–30°C and do not freeze.

Product features

  • Detects IgG, IgM and IgA antibodies to tuberculosis
  • Uses recombinant TB antigens
  • Suitable for whole blood, serum and plasma specimens
  • Compatible with fingerstick and venous whole blood
  • Rapid results in approximately 10 minutes
  • Simple qualitative positive or negative result
  • Internal Control (C) line for procedural validation
  • Convenient cassette format
  • No specialist analyser required
  • Suitable for professional clinical and laboratory settings

Accuracy & Qualtity

The AllTest Tuberculosis Rapid Test Cassette has a relative sensitivity of 86.4%, relative specificity of 99.0% and overall relative accuracy of 96.7% compared with smear and culture results. Intra-assay and inter-assay precision were both greater than 99%, demonstrating consistent performance across the tested specimens and production lots.

Specifications

  • Product Name: Tuberculosis Rapid Test Cassette
  • Manufacturer: AllTest
  • Reference: ITB-402
  • Test Type: Rapid chromatographic immunoassay
  • Target Analytes: Anti-TB antibodies (IgG, IgM and IgA)
  • Target Organism: Mycobacterium tuberculosis
  • Sample Types: Whole blood, serum or plasma
  • Whole Blood Collection: Fingerstick or venous blood
  • Test Format: Cassette
  • Result Type: Qualitative
  • Result Time: 10 minutes
  • Maximum Reading Time: 30 minutes
  • Sample Volume: Approximately 75 µL
  • Buffer Volume: Approximately 40 µL for whole blood samples
  • Storage Temperature: 2–30°C
  • Intended Use: Professional in vitro diagnostic use
  • Control: Internal Control (C) line
  • Interpretation: Positive, negative or invalid
View full details
Your cart
Variant Downloads Price Variant total Quantity Total (Units) Total (GBP)
ALLTEST Tuberculosis Test Kits
Professional Tuberculosis Test Kit ITB-402 (10 Tests - 10 Buffers)ALLTEST ITB-402 TB Whole Blood Testing Kit x 10 Manufactured to order
Professional Tuberculosis Test Kit ITB-402 (10 Tests - 10 Buffers)ALLTEST ITB-402 TB Whole Blood Testing Kit x 10 Buy smaller quantities on
£25.00/ea
£0.00 £25.00/ea
Manufactured to order
0 £0.00
ALLTEST Tuberculosis Test Kits
Professional Tuberculosis Test Kit ITB-402 (40 Tests - 2 Buffers)ALLTEST ITB-402 TB Whole Blood Testing Kit x 40 Manufactured to order Buy smaller quantities on ValueMed
Professional Tuberculosis Test Kit ITB-402 (40 Tests - 2 Buffers)ALLTEST ITB-402 TB Whole Blood Testing Kit x 40 Buy smaller quantities on ValueMed
£60.00/ea
£0.00 £60.00/ea
Manufactured to order
0 £0.00

View cart
0

Total items

£0.00

Product subtotal

Taxes included. Discounts and shipping calculated at checkout.
View cart

Frequently Asked Questions

If you have a question regarding the ALLTEST Tuberculosis Test Kits, send our trade@adtuk.co.uk team an email or give us a call 9-5 weekdays 01263 731168